1.
Water Res ; 213: 118151, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35167966

RESUMO

Antibiotic-resistant bacteria originating from hospitals are ultimately discharged to municipal wastewater treatment plants (WWTP), which may serve as important reservoirs for the spread of antibiotic resistant genes. This study traced and quantified the presence of a rare but clinically relevant antimicrobial resistance gene; Klebsiella pneumoniae carbapenamase (KPC)-and the viable organisms (KPCO) which carried this gene in hospital, non-hospital wastewater discharges, various compartments within a municipal WWTP, receiving water and sediment samples. High concentration of the gene, blaKPC harbored in viable and multispecies KPCO was detected in the hospital wastewater and in the forepart stages of the WWTP, but was not detected in the final effluent following UV disinfection. KPCO were not detected in multiple non-hospital sources of wastewater discharges tested. The treatment train used in the sampled WWTP was found to help remove and reduce KPCO load. Using whole-genome sequencing, a KPC-producing Klebsiella oxytoca strain identical to strains seen in the patients and hospital environment was isolated from the downstream receiving water on one sampling event. KPCO were also found to persist in the biosolids throughout the WWTP, but were not detected in the processed compost-products made from WWTP-biosolids. This study systematically demonstrates dissemination of KPCO from hospital point source to environment via municipal WWTP. Understanding hospitals as the origin and source of spread of some of the most clinically urgent antimicrobial-resistant organisms may help direct interventions that target rate at which antibiotic resistant bacteria evolve and spread via enhancement of wastewater treatment and mitigation of dissemination at source.

2.
ACS ES T Water ; 2(11): 2094-2104, 2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37552737

RESUMO

Congregate living poses one of the highest risk situations for the transmission of respiratory viruses including SARS-CoV-2. University dormitories exemplify such high-risk settings. We demonstrate the value of using building-level SARS-CoV-2 wastewater surveillance as an early warning system to inform when prevalence testing of all building occupants is warranted. Coordinated daily testing of composite wastewater samples and clinical testing in dormitories was used to prompt the screening of otherwise unrecognized infected occupants. We overlay the detection patterns in the context of regular scheduled occupant testing to validate a wastewater detection model. The trend of wastewater positivity largely aligned well with the clinical positivity and epidemiology of dormitory occupants. However, the predictive ability of wastewater-surveillance to detect new positive cases is hampered by convalescent shedding in recovered/noncontagious individuals as they return to the building. Building-level pooled wastewater-surveillance and forecasting is most productive for predicting new cases in low-prevalence instances at the community level. For higher-education facilities and other congregate living settings to remain in operation during a pandemic, a thorough surveillance-based decision-making system is vital. Building-level wastewater monitoring on a daily basis paired with regular testing of individual dormitory occupants is an effective and efficient approach for mitigating outbreaks on university campuses.

3.
Appl Environ Microbiol ; 87(13): e0043321, 2021 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-33858836

RESUMO

Wastewater-based monitoring for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at the individual building level could be an efficient, passive means of early detection of new cases in congregate living settings, but this approach has not been validated. Preliminary samples were collected from a hospital and a local municipal wastewater treatment plant. Molecular diagnostic methods were compared side by side to assess feasibility, performance, and sensitivity. Refined sample collection and processing protocols were then used to monitor two occupied dormitory complexes (n = 105 and 66) over 8 weeks. Wastewater results were validated using known case counts from external clinical testing of building occupants. Results confirm that ultracentrifugation from a 24-h composite collection had a sensitivity of 96.2% and a specificity of 100%. However, the method could not distinguish new infectious cases from persistent convalescent shedding of SARS-CoV-2 RNA. If the detection of convalescent shedding is considered a false positive, then the sensitivity is 100% and specificity drops to 45%. It was determined that the proposed approach constitutes a highly sensitive wastewater surveillance method for detecting SARS-CoV-2, but it could not distinguish new infectious cases from persistent convalescent shedding. Future work must focus on approaches to distinguish new infections from convalescent shedding to fully realize the potential of building wastewater as a surveillance tool for congregate living. IMPORTANCE Some of the most severe outbreaks of COVID-19 have taken place in places where persons live together, such as nursing homes. Wastewater testing from individual buildings could be used for frequent pooled surveillance of virus from all occupants, including those who are contagious, with or without symptoms. This work provides a sensitive practical method for detecting infected individuals, as validated in two building complexes housing occupants who underwent frequent clinical testing performed by external entities. Although this sensitive method could be deployed now for pooled surveillance as an early warning system to limit outbreaks, the study shows that the approach will require further refinement to differentiate contagious, newly infected individuals from persons who have persistent viral fragments shedding in their stool outside the contagious period.


Assuntos
COVID-19/epidemiologia , Instituições Residenciais , SARS-CoV-2/isolamento & purificação , Águas Residuárias/virologia , COVID-19/diagnóstico , Humanos , Técnicas de Diagnóstico Molecular , Reprodutibilidade dos Testes , SARS-CoV-2/genética , Vigilância Epidemiológica Baseada em Águas Residuárias
4.
Appl Environ Microbiol ; 86(24)2020 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-32917755

RESUMO

Hospital wastewater is an increasingly recognized reservoir for resistant Gram-negative organisms. Factors involved in establishment and persistence of Klebsiella pneumoniae carbapenemase-producing organisms (KPCOs) in hospital wastewater plumbing are unclear. This study was conducted at a hospital with endemic KPCOs linked to wastewater reservoirs and robust patient perirectal screening for silent KPCO carriage. Over 5 months, both rooms occupied and rooms not occupied by KPCO-positive patients were sampled at three wastewater sites within each room (sink drain, sink P-trap, and toilet or hopper). Risk factors for KPCO positivity were assessed using logistic regression. Whole-genome sequencing (WGS) identified environmental seeding by KPCO-positive patients. A total of 219/475 (46%) room sampling events were KPCO positive in at least one wastewater site. KPCO-positive patient exposure was associated with increased risk of environmental positivity for the room and toilet/hopper. Previous positivity and intensive care unit room type were consistently associated with increased risk. Tube feeds were associated with increased risk for the drain, while exposure to patients with Clostridioides difficile was associated with decreased risk. Urinary catheter exposure was associated with increased risk of P-trap positivity. P-trap heaters reduced risk of P-trap and sink drain positivity. WGS identified genomically linked environmental seeding in 6 of 99 room occupations by 40 KPCO-positive patients. In conclusion, KPCO-positive patients seed the environment in at least 6% of opportunities; once positive for KPCOs, wastewater sites are at greater risk of being positive subsequently. Increased nutrient exposure, e.g., due to tube food disposal down sinks, may increase risk; frequent flushing may be protective.IMPORTANCEKlebsiella pneumoniae carbapenemase-producing organisms (KPCOs) are bacteria that are resistant to most antibiotics and thus are challenging to treat when they cause infections in patients. These organisms can be acquired by patients who are hospitalized for other reasons, complicating their hospital stay and even leading to death. Hospital wastewater sites, such as sink drains and toilets, have played a role in many reported outbreaks over the past decade. The significance of our research is in identifying risk factors for environmental positivity for KPCOs, which will facilitate further work to prevent transmission of these organisms to patients from the hospital environment.


Assuntos
Proteínas de Bactérias/análise , Infecções por Klebsiella/epidemiologia , Klebsiella pneumoniae/isolamento & purificação , Águas Residuárias/microbiologia , beta-Lactamases/análise , Hospitais , Humanos , Infecções por Klebsiella/microbiologia , Virginia/epidemiologia , Águas Residuárias/análise
5.
Appl Environ Microbiol ; 85(2)2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30367005

RESUMO

An alarming rise in hospital outbreaks implicating hand-washing sinks has led to widespread acknowledgment that sinks are a major reservoir of antibiotic-resistant pathogens in patient care areas. An earlier study using green fluorescent protein (GFP)-expressing Escherichia coli (GFP-E. coli) as a model organism demonstrated dispersal from drain biofilms in contaminated sinks. The present study further characterizes the dispersal of microorganisms from contaminated sinks. Replicate hand-washing sinks were inoculated with GFP-E. coli, and dispersion was measured using qualitative (settle plates) and quantitative (air sampling) methods. Dispersal caused by faucet water was captured with settle plates and air sampling methods when bacteria were present on the drain. In contrast, no dispersal was captured without or in between faucet events, amending an earlier theory that bacteria aerosolize from the P-trap and disperse. Numbers of dispersed GFP-E. coli cells diminished substantially within 30 minutes after faucet usage, suggesting that the organisms were associated with larger droplet-sized particles that are not suspended in the air for long periods.IMPORTANCE Among the possible environmental reservoirs in a patient care environment, sink drains are increasingly recognized as a potential reservoir to hospitalized patients of multidrug-resistant health care-associated pathogens. With increasing antimicrobial resistance limiting therapeutic options for patients, a better understanding of how pathogens disseminate from sink drains is urgently needed. Once this knowledge gap has decreased, interventions can be engineered to decrease or eliminate transmission from hospital sink drains to patients. The current study further defines the mechanisms of transmission for bacteria that colonize sink drains.


Assuntos
Microbiologia do Ar , Escherichia coli/fisiologia , Desinfecção das Mãos , Hospitais , Água/química , Aerossóis/análise , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos , Escherichia coli/isolamento & purificação , Proteínas de Fluorescência Verde/análise , Humanos
6.
Biotechnol Bioeng ; 110(4): 1180-92, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23097129

RESUMO

A laboratory scale semi-batch fed anaerobic ammonia oxidation (ANAMMOX) reactor was operated in the lab under two different feeding operations. In the first scenario, termed as phase I, the reactor was seeded and operated with NO(2) -N added externally with the filtrate to the reactor in the ratio needed for the successful ANAMMOX. A second reactor was also initiated shortly after the start-up of the ANAMMOX to accomplish partial nitrification (nitritation reactor) to generate NO(2) -N. In phase II, the operation of the ANAMMOX reactor was switched to the mode in which case the partially nitrified effluent from the nitritation reactor was fed to the ANAMMOX reactor. In both phases, real filtrate from a local wastewater treatment plant was used as the feed. The ANAMMOX reactor sustained a loading rate (average 0.33 ± 0.03 with a max of 0.4 g N (L day)(-1) ) which is comparable with many other fed-batch reactors in the literature. Consistent total N removal (average of 82 ± 4%) could be sustained in the ANAMMOX reactor during both phases. The nitritation reactor also consistently enabled a NO(2) -N to NH(3) -N ratio of 1.2:1 which was needed for the successful operation of the ANAMMOX reactor in phase II. Sequence analysis and FISH showed that Kuenenia stuttgartiensis dominated the enriched ANAMMOX community along with several unidentified, but seemingly enriched, potential ANAMMOX strains. Microbial ecology analysis for nitritation reactor showed the dominance of Nitrosomonas europaea. In summary, this manuscript provides important information on the start-up and operation of anammox reactor with detailed investigation on microbial ecology in this reactor.


Assuntos
Bactérias Anaeróbias/metabolismo , Reatores Biológicos , Fungos/metabolismo , Anaerobiose , Bactérias Anaeróbias/genética , Sequência de Bases , Primers do DNA , DNA Bacteriano/isolamento & purificação , Filtração , Fungos/genética , Hibridização in Situ Fluorescente , Oxirredução , Filogenia , Reação em Cadeia da Polimerase
7.
Water Res ; 45(2): 694-704, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20950835

RESUMO

This research demonstrates the first ever application of lytic bacteriophage (virus) mediated biocontrol of biomass bulking in the activated sludge process using Haliscomenobacter hydrossis as a model filamentous bacterium. Bacteriophages are viruses that specifically infect bacteria only. The lytic phage specifically infecting H. hydrossis was isolated from the mixed liquor of a local wastewater treatment plant. The isolated bacteriophage belongs to the Myoviridae family with a contractile tail (length-126 nm; diameter-18 nm) and icosahedral head (diameter-81 nm). Titer of the isolated phage with H. hydrossis was calculated to be 5.2 ± 0.3 × 10(5) PFU/mL and burst size was found to be 105 ± 7 PFU/infected cell. The phage was considerably stable after exposure to high temperature (42 °C) and pH between 5 and 8, emphasizing that it can withstand the seasonal/operational fluctuations under real-time applications. Phage to host (bacteria) ratio for the optimal infection was found to be 1:1000 with ∼54% host death. The isolated phage showed no cross infectivity with other bacteria most commonly found in activated sludge systems, thus validating its suitability for biocontrol of filamentous bulking caused by H. hydrossis. Following the phage application, successful reduction in sludge volume index (SVI) from 155 to 105 was achieved, indicating improved biomass settling. The application of phage did not affect nutrient removal efficiency of the biomass, suggesting no collateral damage. Similar to phage therapy in medical applications, phage-mediated biocontrol holds a great potentiality for large-scale applications as economic agent in the mitigation of several water, wastewater and environmental problems. Present study in this direction is a novel effort.


Assuntos
Bacteroidetes/virologia , Biomassa , Myoviridae/genética , Controle Biológico de Vetores/métodos , Esgotos/microbiologia , Bacteriólise , Nefelometria e Turbidimetria
8.
Water Res ; 44(15): 4550-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20630557

RESUMO

Bacteriophages are viruses that infect bacteria and contribute significant changes in the overall bacterial community. Prophages are formed when temperate bacteriophages integrate their DNA into the bacterial chromosome during the lysogenic cycle of the phage infection to bacteria. The prophage (phage DNA integrated into bacterial genome) on the bacterial genome remains dormant, but can cause cell lysis under certain environmental conditions. This research examined the effect of various environmental stress factors on the ammonia oxidation and prophage induction in a model ammonia oxidizing bacteria Nitrosospira multiformis ATCC 25196. The factors included in the study were pH, temperature, organic carbon (COD), the presence of heavy metal in the form of chromium (VI) and the toxicity as potassium cyanide (KCN). The selected environmental factors are commonly encountered in wastewater treatment processes, where ammonia oxidizing bacteria play a pivotal role of converting ammonia into nitrite. All the factors could induce prophage from N. multiformis demonstrating that cell lysis due to prophage induction could be an important mechanism contributing to the frequent upset in ammonia oxidation efficiency in full scale treatment plants. Among the stress factors considered, pH in the acidic range was the most detrimental to the nitrification efficiency by N. multiformis. The number of virus like particles (VLPs) increased by 2.3E+10 at pH 5 in 5h under acidic pH conditions. The corresponding increases in VLPs at pH values of 7 and 8 were 9.67E+9 and 1.57E+10 in 5h respectively. Cell lysis due to stress resulting in phage induction seemed the primary reason for deteriorated ammonia oxidation by N. multiformis at lower concentrations of Cr (VI) and potassium cyanide. However, direct killing of N. multiformis due to the binding of Cr (VI) and potassium cyanide with cell protein as demonstrated in the literature at higher concentrations of these toxic compounds was the primary mechanism of cell lysis of N. multiformis. Organics represented by the chemical oxygen demand (COD) did not have any effect on the phage induction in N. multiformis. This AOB remained dormant at low temperature (4 degrees C) without any phage induction. Significant decrease in the number of live N. multiformis cells with a corresponding increase in the number of VLPs was recorded when the temperature was increased to 35 degrees C. Death of N. multiformis at 45 degrees C was attributed to the destruction of cell wall rather than to the phage induction.


Assuntos
Nitrosomonadaceae/virologia , Prófagos/fisiologia , Vírion/fisiologia , Poluentes Químicos da Água/toxicidade , Amônia/metabolismo , Antibióticos Antineoplásicos/toxicidade , Bacteriólise/efeitos dos fármacos , Cromo/química , Cromo/toxicidade , Concentração de Íons de Hidrogênio , Microscopia Eletrônica , Microscopia de Fluorescência , Mitomicina/toxicidade , Nitrosomonadaceae/metabolismo , Compostos Orgânicos/química , Compostos Orgânicos/toxicidade , Oxirredução/efeitos dos fármacos , Cianeto de Potássio/química , Cianeto de Potássio/toxicidade , Temperatura , Vírion/ultraestrutura , Ativação Viral/efeitos dos fármacos